Chebyshev High-Pass Filter Calculator
A Chebyshev high-pass filter allows a fixed passband ripple in exchange for a steeper cutoff than a maximally flat high-pass filter. Use it to reject low-frequency interference, mains coupling or strong signals in lower bands. Enter the order, cutoff frequency, impedance and ripple to get the series-capacitor / shunt-inductor ladder values, with frequency response and a ripple zoom.
How to use
- Enter the order n (1–9, odd only). Raise the order or the ripple for a steeper cutoff.
- Enter the cutoff frequency fc (MHz, lower passband edge), the system impedance Zo (usually 50 Ω) and the passband ripple (dB).
- Click Calculate. The table lists capacitors (pF) and inductors (nH) for both Type 1 and Type 2 circuits.
- Choose a topology from the circuit diagram: capacitors go in the series positions and inductors to ground. Select the nearest standard values and tune by measurement.
Theory and formulas
First the Chebyshev low-pass prototype values gk are computed from the order n and the ripple Lr (dB):
γ = sinh( β / 2n )
ak = sin( (2k − 1)π / 2n ) bk = γ² + sin²( kπ / n )
g1 = 2a1 / γ gk = 4ak−1ak / ( bk−1 · gk−1 ), k = 2 … n
The low-pass to high-pass transformation then turns each series inductor into a series capacitor and each shunt capacitor into a shunt inductor, with reciprocal values:
C = 1 / (gk · Zo · ωc) L = Zo / (gk · ωc)
Ripple and matching
The response is |H(f)|² = 1 / (1 + ε²Tn²(fc/f)) with ε² = 10Lr/10 − 1. The worst passband return loss is RL = −10·log10(1 − 10−Lr/10): about 16.4 dB for 0.1 dB ripple and 9.6 dB for 0.5 dB. Only odd orders are offered because they are terminated in Zo at both ends and need no extra matching.
Design tips
- Use C0G/NP0 series capacitors and high-Q shunt inductors whose self-resonant frequency is well above the highest passband frequency; otherwise inductor self-resonance creates notches at the top of the band.
- Chebyshev element values are more sensitive to tolerance. Use parts of ±2% or better and leave pads for tuning.
- Keep the ground connection of each shunt inductor short and direct (several ground vias); ground inductance reduces stopband rejection.
- For a perfectly flat passband use the maximally flat high-pass; if only one band needs to pass, consider the Chebyshev band-pass.
FAQ
- Where are high-pass filters used?
- They block signals below the operating band, for example low-frequency interference, DC and mains noise, or to separate the upper band in multi-band systems.
- What is the difference between Type 1 and Type 2?
- Type 1 starts with a series capacitor, so the input is DC-blocked. Type 2 starts with a shunt inductor, giving the input a DC path to ground, which is useful for draining static charge or DC. Both have the same frequency response.
- Is fc the −3 dB point?
- No. Here fc is the passband edge where the attenuation equals the ripple; the actual −3 dB point of a high-pass filter is slightly below fc.