Home › RF Design Tools › Filters › Chebyshev high-pass filter
RF DESIGN TOOL · FILTER

Chebyshev High-Pass Filter Calculator

A Chebyshev high-pass filter allows a fixed passband ripple in exchange for a steeper cutoff than a maximally flat high-pass filter. Use it to reject low-frequency interference, mains coupling or strong signals in lower bands. Enter the order, cutoff frequency, impedance and ripple to get the series-capacitor / shunt-inductor ladder values, with frequency response and a ripple zoom.

Equal-ripple passbandOrder 1–9 (odd)Type 1 (series C first) / Type 2 (shunt L first)C in pF · L in nH

① Input parameters

Ripple is the maximum allowed variation in the passband (dB), typically 0.01–0.5 dB. fc is the passband edge (where the attenuation equals the ripple); frequencies above fc are passed. Only odd orders are accepted; an even entry is increased by 1 automatically.

② Results

#Type 1ValueType 2Value
1C1pFL1nH
2L1nHC1pF
3C2pFL2nH
4L2nHC2pF
5C3pFL3nH
6L3nHC3pF
7C4pFL4nH
8L4nHC4pF
9C5pFL5nH

Only the first n elements are shown. In Type 1, C are series capacitors and L are shunt inductors to ground; Type 2 is the reverse. Pick the nearest standard (E24) values and fine-tune by measurement.

Circuit diagram

C1C2C3C4L1L2L3L4 INGND · continues up to order n

Frequency response (current inputs)

Ideal response: |H(f)|² = 1 / (1 + ε²·Tn²(fc/f)), with ε² = 10ripple/10 − 1. Above fc is the passband, varying between 0 and −ripple dB; below fc the response falls off quickly.

Passband ripple (zoomed)

The vertical axis is expanded to a few dB; the orange dashed line marks the ripple setting. The ripple is concentrated near fc and flattens towards 0 dB at higher frequencies.

How to use

  1. Enter the order n (1–9, odd only). Raise the order or the ripple for a steeper cutoff.
  2. Enter the cutoff frequency fc (MHz, lower passband edge), the system impedance Zo (usually 50 Ω) and the passband ripple (dB).
  3. Click Calculate. The table lists capacitors (pF) and inductors (nH) for both Type 1 and Type 2 circuits.
  4. Choose a topology from the circuit diagram: capacitors go in the series positions and inductors to ground. Select the nearest standard values and tune by measurement.

Theory and formulas

First the Chebyshev low-pass prototype values gk are computed from the order n and the ripple Lr (dB):

β = ln[ coth( Lr / 17.37 ) ] (Lr = ripple in dB)
γ = sinh( β / 2n )
ak = sin( (2k − 1)π / 2n )  bk = γ² + sin²( kπ / n )
g1 = 2a1 / γ  gk = 4ak−1ak / ( bk−1 · gk−1 ), k = 2 … n

The low-pass to high-pass transformation then turns each series inductor into a series capacitor and each shunt capacitor into a shunt inductor, with reciprocal values:

ωc = 2π · fc
C = 1 / (gk · Zo · ωc)  L = Zo / (gk · ωc)

Ripple and matching

The response is |H(f)|² = 1 / (1 + ε²Tn²(fc/f)) with ε² = 10Lr/10 − 1. The worst passband return loss is RL = −10·log10(1 − 10−Lr/10): about 16.4 dB for 0.1 dB ripple and 9.6 dB for 0.5 dB. Only odd orders are offered because they are terminated in Zo at both ends and need no extra matching.

Design tips

FAQ

Where are high-pass filters used?
They block signals below the operating band, for example low-frequency interference, DC and mains noise, or to separate the upper band in multi-band systems.
What is the difference between Type 1 and Type 2?
Type 1 starts with a series capacitor, so the input is DC-blocked. Type 2 starts with a shunt inductor, giving the input a DC path to ground, which is useful for draining static charge or DC. Both have the same frequency response.
Is fc the −3 dB point?
No. Here fc is the passband edge where the attenuation equals the ripple; the actual −3 dB point of a high-pass filter is slightly below fc.

Related design tools

Designing an RF product? WENSHING supplies RF transceiver modules, LoRa modules, SMD ceramic antennas, directional antennas and UHF RFID readers, and supports custom RF circuit design.

Contact an engineer