Home › RF Design Tools › Transmission Lines › Coaxial line
Coaxial Line Impedance Calculator
A coaxial line is an inner conductor, dielectric and outer conductor (ground) arranged concentrically, with the field fully enclosed — the most common interconnect in RF systems. Enter the dimensions to get impedance, L/C per length and delay, or synthesize the size for 50 Ω or 75 Ω.
Analyze d, D → ZoSynthesize D or dL, C per lengthDelay in ns/mTEM, no dispersion
How to use
- Enter the dielectric εr (PTFE 2.1, solid PE 2.25, air 1).
- Known dimensions: enter the inner diameter d and outer conductor inner diameter D and press Analyze for Zo, C, L, Vp and td.
- Designing for an impedance: enter the target Zo, then keep d and press Find D, or keep D and press Find d; the result is written into the D or d field.
Theory and formulas
Coax is a TEM line with the field entirely in the dielectric, so the formulas are exact:
Zo = (60/√εr) · ln(D/d) Ω
C = 2πε0εr / ln(D/d) ≈ 55.556 · εr / ln(D/d) pF/m
L = (μ0/2π) · ln(D/d) = 200 · ln(D/d) nH/m
Vp = c/√εr ≈ 3×10⁵ / √εr km/s
td = √εr / c ≈ 3.33 · √εr ns/m
Synthesis: D = d · eZo√εr/60 d = D / eZo√εr/60
C = 2πε0εr / ln(D/d) ≈ 55.556 · εr / ln(D/d) pF/m
L = (μ0/2π) · ln(D/d) = 200 · ln(D/d) nH/m
Vp = c/√εr ≈ 3×10⁵ / √εr km/s
td = √εr / c ≈ 3.33 · √εr ns/m
Synthesis: D = d · eZo√εr/60 d = D / eZo√εr/60
Design tips
- Common D/d ratios: for 50 Ω, PTFE (εr 2.1) ≈ 3.35, solid PE (2.25) ≈ 3.49, air ≈ 2.30; for 75 Ω solid PE ≈ 6.52.
- Air coax has minimum loss near 77 Ω and maximum power handling near 30 Ω; 50 Ω is the compromise that became the RF standard.
- D is the outer diameter of the dielectric (inner surface of the outer conductor), not the cable jacket diameter.
- Stay below the first higher-order mode: fc ≈ c / [ π(D + d)/2 · √εr ]; above it the TE11 mode can propagate.
FAQ
- Why are coax cables mostly 50 Ω or 75 Ω?
- 75 Ω is close to the minimum-loss point of air coax and is used for TV and video; 50 Ω balances power handling and loss for RF communication and test.
- What is the delay td used for?
- It converts cable length into phase and time delay — e.g. feed-line compensation in phased arrays, or locating a fault from a TDR time reading.
- Synthesis changed my D or d field?
- Yes. The synthesized dimension is written into the D or d field, and C, L, Vp and td update together.