When simulating microstrip lines, antenna feeds or filters in HFSS, a wave port that is too small squeezes the fields and skews the impedance, while one that is too large may let higher-order modes propagate. Enter the trace width and substrate height to estimate the port width and height as a starting point.

For 50 Ω microstripAny unit (same for both)Width and height at onceCross-section diagram

① Input Parameters

Units do not matter, but w and h must use the same unit; the results are in that unit too. The result is only an estimate – always run Solve Ports Only to confirm the port.

② Results

ItemValue (same unit as input)
Wave port width
Wave port height
Height factor
Legacy width (emtalk)
Legacy height (emtalk)

Results follow the Ansys HFSS wave-port guideline (4 significant digits); the legacy emtalk formula is listed below for comparison.

Wave Port Dimensions

whPort widthPort heightWave PortSubstrateTraceGround

The orange dashed frame is the HFSS wave port: its bottom edge sits on the ground plane, it is perpendicular to the microstrip, and it encloses the fields above and beside the trace.

How to Use

  1. Enter the microstrip trace width w and substrate height h in the same unit (mil or µm recommended).
  2. Click Calculate to get the estimated wave port width and height.
  3. In HFSS draw a rectangular port of that size on the model boundary, bottom edge on the ground plane, trace centered.
  4. Run Solve Ports Only first and check that the port impedance is close to 50 Ω with a single propagating mode before the full simulation.

Theory & Formulas

Following the Ansys HFSS guideline, the tool estimates the microstrip wave-port size from trace width w, substrate height h and permittivity εr:

If w ≥ h: Port width = 10 × w
If w < h: Port width = max( 5 × w , 4 × h )
Port height = k × h, k = 6–10 (lower εr → closer to 10: εr≤2 → 10h, εr≥10 → 6h, linear in between)

Based on the Ansys HFSS microstrip wave-port guideline (height 6h–10h; width 10w for w≥h, 5w or 3–4h for w<h). The previous version of this page used the emtalk formula, which makes the port height equal to the trace width when w≥h; the main result now follows the official guideline and the legacy formula is shown for reference only.

Port sizing principles

The wave port is where HFSS solves the 2D cross-section modes. It must be wide enough that the fringing fields beside the trace have largely decayed at the port edges, and tall enough to contain the fields above the substrate; but if it is too large the port outline behaves like a waveguide and higher-order modes may propagate in your band. Keep the port large enough but not excessive, and verify with Solve Ports Only.

Design Tips

FAQ

Which unit should I use?
Any unit, as long as w and h are the same. Because the results are rounded to integers, mil or µm works better than mm.
Can I use it for coplanar waveguide or stripline?
The calculation assumes a 50 Ω microstrip line; for other structures it is only a rough starting point and must be checked with Solve Ports Only.
Why run Solve Ports Only first?
It solves only the 2D port modes, which is fast, and confirms the port impedance and modes before you spend time on the full 3D solve.

Related Design Tools

Designing an RF product? WENSHING supplies RF transceiver modules, LoRa modules, SMD ceramic antennas, directional antennas and UHF RFID readers, and offers custom RF circuit design support.

Contact an Engineer