中文
English
Home > Products > Data Transmission> Wireless Data Transceiver > Remote Wireless Data Controller | Long-Range Links for Pump Stations and Plant Equipment

Remote Wireless Data Controller | Long-Range Links for Pump Stations and Plant Equipment

Model:
RD-232WIFI

Install one unit at each end and this wireless data controller replaces the cable between field equipment and the control room. A pump station sends water level and motor status back, and the control room switches the pumps remotely; meters and controllers across a site can link to the central computer without trenching.

It plugs into the equipment's existing RS232 or RS485 port, so to the equipment it is just another cable and nothing needs reprogramming. The standard-power version covers short links, and the high-power version spans sites or hills. One unit in the control room can poll several in the field, and on temporary job sites it installs quickly and leaves just as easily.

When field equipment is far from the control room and cabling is a hassle, put one unit at each end and the data and control commands that used a cable go over the air instead. Suited to pump stations, water towers, plants and farms where distances are long.

Where it is used

Pump stations and water towers

Water level and motor status come back to the control room, which switches pumps remotely.

Plant equipment links

Controllers and meters at the far end of a site talk to the central PC without trenching cable.

PC reading remote meters

A computer reads distant meters or equipment data wirelessly and logs it on schedule.

Temporary and outdoor sites

Short-term links on construction sites or outdoor venues are quick to set up and remove.

Features

  • No long cable runs
    One unit at each end replaces the communication cable.
  • Long distances
    Standard-power and high-power versions to match the distance.
  • Existing equipment connects directly
    It plugs into the equipment’s existing communication port, so the system is unchanged.
  • Two-way
    Data comes back and commands go out.

How to use it

  1. 1Check the distance and obstructions between the two points, and decide on the power version and antenna position.
  2. 2Connect one unit to the field equipment port and one to the control room PC or controller.
  3. 3Set the same channel and communication settings at both ends, power up and test data in both directions.
  4. 4Mount antennas high and clear of metal; go live once the link is stable.

How to choose

Check the distance first, then which port the equipment uses (ask the equipment maker or installer):

Short distance, little in between
Standard-power version
Across a site, past hills or very far
High-power version
Equipment port is RS232
RS232 interface
Equipment port is RS485
RS485 interface

Tell us the distance and the equipment port and we quote the matching version; frequency, power and supply are in the specifications below.

FAQ

Q:Does the existing system need changes?

Usually not; to the equipment it is like a cable plugged into the same port.

Q:How far can it reach?

The standard-power version suits links within a site, the high-power version reaches across sites and past hills; mounting antennas high and clear of metal extends the range. Ranges per version are in the specifications below.

Q:Can one unit talk to several?

Yes, one unit in the control room polls several in the field; tell us the number of devices and we set up channels and addresses.

Q:Can it be used for medical or traffic signal systems?

It is built for general industrial and public equipment; for medical, aviation, traffic signal or other life-safety systems, use equipment made for that industry.

▼ Specifications, product views and downloads follow below

INTERFACE


 RFID|Wireless Modules|RF Module|Wireless VIDEO   MetInfo enterprise content manager system | MetInfo CMS  


APPEARANCE

External Appearance

Dimensions - remote wireless network controller RD-232WIFI


FEATURES

Application



Camera pan tilt control - remote wireless network controller RD-232WIFI

Automatic meter reading - remote wireless network controller RD-232WIFI

Rs232 server attendance terminal - remote wireless network controller RD-232WIFI


SPECIFICATION

Technical specifications 

  • 432~436MHzMHz

  • UHF Band Wireless Data Transceiver

  • RF Output Power up to 5W 

  • Distance:20KM(5W)  /  700m~2KM(0.5W)

  • Sensitivity up to -129dBm(512bps) under

  • RS232/RS485 Interface

  • Transceiver Data Rate 1.6Kbps~128Kbps

ParameterMinTypMaxUnitCondition
Operating Condition
Operating Temperature Range-10
+70℃
Operating Supply Voltage91218V
Current Consumption
RX Mode
37
mADC12V
TX Mode (RD232HI0.5W)
200
mADC 12V Peak
TX Mode(RD232HI5W)
1800
mADC 12V Peak
RF Characteristic
Frequency Range432434436MHz
Data Rate1.8
172.8KbpsGFSK
TX Output Power(RD232HI0.5W)
27.528dBm
TX Output Power(RD232HI5W)
3737.2dBm
RX Sensitivity
-126-129dBm
Modulation
GFSK


Other
ESD

2000V
Interface Data Rate1.2
115.2Kbps

Key specifications at a glance

ModelRD-232WIFI
Frequency432~436MHz
ApplicationWireless data transmission, Industrial control
Product categoryWireless Data Transceiver

Compare Wireless Data Transceiver models

RD-232WIFI Wireless Hopping Controller Transceiver and other models in the same WENSHING category — select a model to see its full details.

ProductModelFrequencyApplication
RD-232WIFI Wireless Hopping Controller TransceiverRD-232WIFI432~436MHzWireless data transmission, Industrial control
WS-PLCMU700 Wireless PLC Bridge | RS-485/RJ45 to Wi-Fi, Mesh & LoRa Modbus GatewayWS-PLCMU700industrial control, building automation
RD232-HW-925M Wide Voltage Hi Power Radio ModemRD232-HW-RS485-925M / RD232-HW-TTL-925M902~928MHzWireless data transmission, Industrial control
WS-RDL Remote Network ControllerWS-RDL-R4 / WS-RDL-R9 / WS-RDL-L4 / WS-RDL-L9 / WS-RDL-LD / WS-RDL-WiFi433MHz/925MHz/2.4GHzWireless data transmission, Industrial control
RD232-H-434M Hi Power Radio ModemRD232-H-RS232-434M / RD232-H-RS485-434M / RD232-H-USB-434M / RD232-H-TTL-434M432~436MHzWireless data transmission, Industrial control
RD232-HW-434M Wide Voltage Hi Power Radio ModemRD232-HW-RS485-434M / RD232-HW-TTL-434M432~436MHzWireless data transmission, Industrial control
RD-232HI-4M5W 5W Hi Power Radio ModemRD-232HI-4M5W / RD-232HI-4MW5432~436MHzWireless data transmission, Industrial control
RD-232HI-9M2W 2W Hi Power Radio ModemRD-232HI-9M2W / RD-232HI-9MW5902~928MHzWireless data transmission, Industrial control
RD232-H WiFi Hi Power Wireless TransceiverRD-485-WiFi2.4GHzWireless data transmission, Industrial control

Need help choosing? browse all Wireless Data Transceiver products or contact our engineers for specifications, samples or a quotation.

For procurement & tender teams

434MHz remote wireless control and data tender checklist

This checklist compares the this product remote wireless network controller with requirements that often appear when integrators buy remote controllers or wireless RS-232 / RS-485 links. Items marked "Stated" are in the specifications on this page.

✔ Stated on this page

1. Common tender requirements vs. this product

Frequency band✔ Stated
Typical wording: Licence-free sub-GHz band
432–436 MHz (typ. 434 MHz).
RX sensitivity✔ Stated
Typical wording: Sensitivity better than a stated dBm
−126 dBm typ., −129 dBm max.
Modulation and data rate✔ Stated
Typical wording: Configurable air and serial rates
GFSK, 1.8–172.8 kbps; interface rate 1.2–115.2 kbps.
Serial interface✔ Stated
Typical wording: RS-232 / RS-485 port
RS232 and RS485.
Power supply✔ Stated
Typical wording: 12 V DC supply
9–18 V (typ. 12 V); 37 mA receive.
Operating temperature✔ Stated
Typical wording: Range such as −10 to +60°C or wider
−10 to +70 °C.
ESD protection✔ Stated
Typical wording: Surge / ESD protection
ESD 2000 V.

2. Applications: who buys it and where it is used

Remote control of general equipment
Send control commands to general equipment on 434MHz.
Wireless data
Send RS232 / RS485 equipment data wirelessly.
Home appliance control (earlier page)
Wireless control of general home appliances.
Office equipment control (earlier page)
Remote operation of office equipment.
Any site that needs a wireless link (earlier page)
General places where cabling is hard and wireless control is needed.

3. Procurement FAQ

Interfaces?
RS232 and RS485, interface rate 1.2–115.2 kbps.
Band?
432–436 MHz.
Supply voltage?
9–18 V (typ. 12 V), 37 mA receive.
Can it be used in medical, transport or life-safety equipment?
No. The page states it is for general equipment only, not for medical, aviation, transport or life-safety systems.
Air data rate?
1.8–172.8 kbps, GFSK.
What should an integrator or plant send us for a quotation?
Please send the quantity, the interface needed (RS232 / RS485 / TTL / USB), the equipment at both ends and its serial settings, the distance and obstacles between the two ends, the power source, and whether the link is point-to-point or one-to-many.

"Typical wording" summarises requirements seen in public procurement documents in Taiwan and abroad. Performance of this product is as stated in the specifications on this page and the official datasheet.