Mini-Interrogator System
MI-108
Model : MI-108
Mini-Interrogator System

Products Application

1.Applied for : small community district, factory, hospital, electric power & remote control the equipment......


2.Applied for : small community district, factory, hospital, electric power & remote control the equipment......


Programing instruction

This software is applied for set any kind of parameter of RFS tation device,for get the data from hardware device or user computerize theinformation,beside, managing the users information (Add Record, Modi Record,Del Record,Query,Previous & Sort),then through Serious port forwarding out the information.

Programing Logic insstruction


Data format :

Type Byte Text Byte Byte
Meaning Account status attend informion Series Data Rate Frequency
Data un-exclusive un-exclusive un-exclusive un-exclusive
Length Byte 1 100 1 1

1.User information

Type double precision Test Test length
Meaning Users account Users name Users address ID code
Data un-exclusive un-exclusive un-exclusive un-exclusive
Length Byte 8 30 100 4

2.User diary information

Type double precision Text Text Text time
Meaning Users account Users name Tele No. sending data the matter time
Date un-exclusive un-exclusive un-exclusive un-exclusive un-exclusive
Length Byte 8 >30 20 100 **

3. The data afferent of hardware

Type Text Text Text Text
Meaning Users account Tele No. User message reserve
Data exclusive un-exclusive un-exclusive exclusive
Length Byte 11 20 100 4

Programing using instruction

1.Hardware connection
Settig the RFStation Device.
2. bootloader
<1>Compressed the programming to a document file, example : D : under : \RFSTATION, and get RFStation.exe, dbuserInfo.mdb and thiscovering documents, double click RFStation.exe, you will finish the bootloader.
<2>Bootloader port as following instruction :

2.Programing application instruction
1.Common Panel
1).Sending message ( handed transmite ).
a. SeriPort.
b.Select Baudrate of RFStation device.
c. Choise the way of Query from the select frame.
d. Inset the query code in the Query edit frame.
e.Click Query buttom.
f. Setting the message.
g. Inset re-call Tel No.
h. Select log On.
I. Click send buttom.
2).Record Management :
a. Add Record : All the operation will be covered during adding record,only just backout edith model to continue operation.
b. ModiRecord : All the operation will be covered during modify record, only just updatethe model for continue operation. Remark : the account number can not be changed as well as ID number could not repeat
c. Del Record : For delete the record
d. Previous,Next : Using for up and down remove the record

2. View Records
a. Display : Display all users record
b. Query : Query all the record of satisfactory, and display
c. Sort : Select the way of sort (ASC,DESC) as well as the Kwac of sort

3. View Logs
d.Display : Display all users logs.
e. Query : Query all the logs of satisfactory, and display.
f. Sort : Select the way of sort ( ASC, DESC) as well as the Kwac of sort.

I have a question:

Name:     
Title:         
E-mail:     
Address: 
Q&A content:
Public message Suggestion for WENSHING not for public